Insulated End-Sleeves
- For establishing solderless, electrical connections according to DIN
- Surface galvanically tin-plated
- Insulated, halogen-free and temperature resistant up to 105°C
- Material made of Cu (copper)
- Insulation sleeve made of PP (Polypropylene)
| Article |
|
|
|
|
|
|
|
|
|
|
|---|---|---|---|---|---|---|---|---|---|---|
| 144I-0,25-6 |
Length - mm
12
|
Type pressing
|
Sleeve length - mm
6
|
Insulation length - mm
6
|
Pressing area - mm²
0,25
|
Pressing area - AWG
23
|
Weight - g
45
|
Packing unit
1000
|
Barcode
40 03758 14445 9
|
|
| 144I-0,25-8 |
Length - mm
14
|
Type pressing
|
Sleeve length - mm
8
|
Insulation length - mm
6
|
Pressing area - mm²
0,25
|
Pressing area - AWG
23
|
Weight - g
50
|
Packing unit
1000
|
Barcode
40 03758 14446 6
|
|
| 144I-0,34-6 |
Length - mm
12
|
Type pressing
|
Sleeve length - mm
6
|
Insulation length - mm
6
|
Pressing area - mm²
0,34
|
Pressing area - AWG
22
|
Weight - g
45
|
Packing unit
1000
|
Barcode
40 03758 14448 0
|
|
| 144I-0,34-8 |
Length - mm
14
|
Type pressing
|
Sleeve length - mm
8
|
Insulation length - mm
6
|
Pressing area - mm²
0,34
|
Pressing area - AWG
22
|
Weight - g
50
|
Packing unit
1000
|
Barcode
40 03758 14449 7
|
|
| 144I-0,5-6 |
Length - mm
12
|
Type pressing
|
Sleeve length - mm
6
|
Insulation length - mm
6
|
Pressing area - mm²
0,5
|
Pressing area - AWG
20
|
Weight - g
70
|
Packing unit
1000
|
Barcode
40 03758 14453 4
|
|
| 144I-0,5-8 |
Length - mm
14
|
Type pressing
|
Sleeve length - mm
8
|
Insulation length - mm
6
|
Pressing area - mm²
0,5
|
Pressing area - AWG
20
|
Weight - g
70
|
Packing unit
1000
|
Barcode
40 03758 14470 1
|
|
| 144I-0,5-10 |
Length - mm
16
|
Type pressing
|
Sleeve length - mm
10
|
Insulation length - mm
6
|
Pressing area - mm²
0,5
|
Pressing area - AWG
20
|
Weight - g
85
|
Packing unit
1000
|
Barcode
40 03758 14452 7
|
|
| 144I-0,75-6 |
Length - mm
12
|
Type pressing
|
Sleeve length - mm
6
|
Insulation length - mm
6
|
Pressing area - mm²
0,75
|
Pressing area - AWG
18
|
Weight - g
80
|
Packing unit
1000
|
Barcode
40 03758 14459 6
|
|
| 144I-0,75-8 |
Length - mm
14
|
Type pressing
|
Sleeve length - mm
8
|
Insulation length - mm
6
|
Pressing area - mm²
0,75
|
Pressing area - AWG
18
|
Weight - g
80
|
Packing unit
1000
|
Barcode
40 03758 14471 8
|
|
| 144I-0,75-10 |
Length - mm
16
|
Type pressing
|
Sleeve length - mm
10
|
Insulation length - mm
6
|
Pressing area - mm²
0,75
|
Pressing area - AWG
18
|
Weight - g
100
|
Packing unit
1000
|
Barcode
40 03758 14454 1
|
|
| 144I-0,75-12 |
Length - mm
18
|
Type pressing
|
Sleeve length - mm
12
|
Insulation length - mm
6
|
Pressing area - mm²
0,75
|
Pressing area - AWG
18
|
Weight - g
105
|
Packing unit
1000
|
Barcode
40 03758 14458 9
|
|
| 144I-1,0-6 |
Length - mm
12
|
Type pressing
|
Sleeve length - mm
6
|
Insulation length - mm
6
|
Pressing area - mm²
1
|
Pressing area - AWG
17
|
Weight - g
90
|
Packing unit
1000
|
Barcode
40 03758 14480 0
|
|
| 144I-1,0-8 |
Length - mm
14
|
Type pressing
|
Sleeve length - mm
8
|
Insulation length - mm
6
|
Pressing area - mm²
1
|
Pressing area - AWG
17
|
Weight - g
100
|
Packing unit
1000
|
Barcode
40 03758 14472 5
|
|
| 144I-1,0-10 |
Length - mm
16
|
Type pressing
|
Sleeve length - mm
10
|
Insulation length - mm
6
|
Pressing area - mm²
1
|
Pressing area - AWG
17
|
Weight - g
120
|
Packing unit
1000
|
Barcode
40 03758 14447 3
|
|
| 144I-1,0-12 |
Length - mm
18
|
Type pressing
|
Sleeve length - mm
12
|
Insulation length - mm
6
|
Pressing area - mm²
1
|
Pressing area - AWG
17
|
Weight - g
125
|
Packing unit
1000
|
Barcode
40 03758 14479 4
|
|
| 144I-1,5-8 |
Length - mm
14
|
Type pressing
|
Sleeve length - mm
8
|
Insulation length - mm
6
|
Pressing area - mm²
1,5
|
Pressing area - AWG
15
|
Weight - g
110
|
Packing unit
1000
|
Barcode
40 03758 14473 2
|
|
| 144I-1,5-10 |
Length - mm
16
|
Type pressing
|
Sleeve length - mm
10
|
Insulation length - mm
6
|
Pressing area - mm²
1,5
|
Pressing area - AWG
15
|
Weight - g
130
|
Packing unit
1000
|
Barcode
40 03758 14481 7
|
|
| 144I-1,5-12 |
Length - mm
18
|
Type pressing
|
Sleeve length - mm
12
|
Insulation length - mm
6
|
Pressing area - mm²
1,5
|
Pressing area - AWG
15
|
Weight - g
150
|
Packing unit
1000
|
Barcode
40 03758 14482 4
|
|
| 144I-1,5-18 |
Length - mm
24
|
Type pressing
|
Sleeve length - mm
18
|
Insulation length - mm
6
|
Pressing area - mm²
1,5
|
Pressing area - AWG
15
|
Weight - g
190
|
Packing unit
1000
|
Barcode
40 03758 14483 1
|
|
| 144I-2,5-8 |
Length - mm
14
|
Type pressing
|
Sleeve length - mm
8
|
Insulation length - mm
6
|
Pressing area - mm²
2,5
|
Pressing area - AWG
13
|
Weight - g
150
|
Packing unit
1000
|
Barcode
40 03758 14474 9
|
|
| 144I-2,5-12 |
Length - mm
18
|
Type pressing
|
Sleeve length - mm
12
|
Insulation length - mm
6
|
Pressing area - mm²
2,5
|
Pressing area - AWG
13
|
Weight - g
200
|
Packing unit
1000
|
Barcode
40 03758 14486 2
|
|
| 144I-2,5-18 |
Length - mm
24
|
Type pressing
|
Sleeve length - mm
18
|
Insulation length - mm
6
|
Pressing area - mm²
2,5
|
Pressing area - AWG
13
|
Weight - g
250
|
Packing unit
1000
|
Barcode
40 03758 14487 9
|
|
| 144I-4,0-10 |
Length - mm
17
|
Type pressing
|
Sleeve length - mm
10
|
Insulation length - mm
7
|
Pressing area - mm²
4
|
Pressing area - AWG
11
|
Weight - g
210
|
Packing unit
100
|
Barcode
40 03758 14475 6
|
|
| 144I-4,0-12 |
Length - mm
20
|
Type pressing
|
Sleeve length - mm
12
|
Insulation length - mm
8
|
Pressing area - mm²
4
|
Pressing area - AWG
11
|
Weight - g
250
|
Packing unit
100
|
Barcode
40 03758 14354 4
|
|
| 144I-4,0-18 |
Length - mm
26
|
Type pressing
|
Sleeve length - mm
18
|
Insulation length - mm
8
|
Pressing area - mm²
4
|
Pressing area - AWG
11
|
Weight - g
320
|
Packing unit
100
|
Barcode
40 03758 14355 1
|
|
| 144I-6,0-12 |
Length - mm
20
|
Type pressing
|
Sleeve length - mm
12
|
Insulation length - mm
8
|
Pressing area - mm²
6
|
Pressing area - AWG
10
|
Weight - g
350
|
Packing unit
100
|
Barcode
40 03758 14476 3
|
|
| 144I-6,0-18 |
Length - mm
26
|
Type pressing
|
Sleeve length - mm
18
|
Insulation length - mm
8
|
Pressing area - mm²
6
|
Pressing area - AWG
10
|
Weight - g
460
|
Packing unit
100
|
Barcode
40 03758 14358 2
|
|
| 144I-10,0-12 |
Length - mm
22
|
Type pressing
|
Sleeve length - mm
12
|
Insulation length - mm
10
|
Pressing area - mm²
10
|
Pressing area - AWG
7
|
Weight - g
450
|
Packing unit
100
|
Barcode
40 03758 14477 0
|
|
| 144I-10,0-18 |
Length - mm
28
|
Type pressing
|
Sleeve length - mm
18
|
Insulation length - mm
10
|
Pressing area - mm²
10
|
Pressing area - AWG
7
|
Weight - g
650
|
Packing unit
100
|
Barcode
40 03758 14484 8
|
|
| 144I-16,0-12 |
Length - mm
24
|
Type pressing
|
Sleeve length - mm
12
|
Insulation length - mm
12
|
Pressing area - mm²
16
|
Pressing area - AWG
5
|
Weight - g
650
|
Packing unit
100
|
Barcode
40 03758 14478 7
|
|
| 144I-16,0-18 |
Length - mm
28
|
Type pressing
|
Sleeve length - mm
18
|
Insulation length - mm
10
|
Pressing area - mm²
16
|
Pressing area - AWG
5
|
Weight - g
800
|
Packing unit
100
|
Barcode
40 03758 14485 5
|
|
| 144I-25,0-16 |
Length - mm
30
|
Type pressing
|
Sleeve length - mm
16
|
Insulation length - mm
14
|
Pressing area - mm²
25
|
Pressing area - AWG
3
|
Weight - g
1600
|
Packing unit
50
|
Barcode
40 03758 14488 6
|
|
| 144I-25,0-18 |
Length - mm
32
|
Type pressing
|
Sleeve length - mm
18
|
Insulation length - mm
14
|
Pressing area - mm²
25
|
Pressing area - AWG
3
|
Weight - g
1700
|
Packing unit
50
|
Barcode
40 03758 14489 3
|
|
| 144I-25,0-22 |
Length - mm
36
|
Type pressing
|
Sleeve length - mm
22
|
Insulation length - mm
14
|
Pressing area - mm²
25
|
Pressing area - AWG
3
|
Weight - g
2000
|
Packing unit
50
|
Barcode
40 03758 14350 6
|
|
| 144I-35,0-16 |
Length - mm
30
|
Type pressing
|
Sleeve length - mm
16
|
Insulation length - mm
14
|
Pressing area - mm²
35
|
Pressing area - AWG
2
|
Weight - g
1900
|
Packing unit
50
|
Barcode
40 03758 14351 3
|
|
| 144I-35,0-18 |
Length - mm
32
|
Type pressing
|
Sleeve length - mm
18
|
Insulation length - mm
14
|
Pressing area - mm²
35
|
Pressing area - AWG
2
|
Weight - g
2100
|
Packing unit
50
|
Barcode
40 03758 14352 0
|
|
| 144I-35,0-25 |
Length - mm
39
|
Type pressing
|
Sleeve length - mm
25
|
Insulation length - mm
14
|
Pressing area - mm²
35
|
Pressing area - AWG
2
|
Weight - g
2500
|
Packing unit
50
|
Barcode
40 03758 14353 7
|
|
| 144I-50,0-20 |
Length - mm
36
|
Type pressing
|
Sleeve length - mm
20
|
Insulation length - mm
16
|
Pressing area - mm²
50
|
Pressing area - AWG
0
|
Weight - g
3300
|
Packing unit
50
|
Barcode
40 03758 14356 8
|
|
| 144I-50,0-25 |
Length - mm
40
|
Type pressing
|
Sleeve length - mm
25
|
Insulation length - mm
15
|
Pressing area - mm²
50
|
Pressing area - AWG
0
|
Weight - g
3600
|
Packing unit
50
|
Barcode
40 03758 14357 5
|
Crimp material
All cable connectors and terminal sleeves are temperature-resistant up to 105 °C and are available in special sizes in addition to the standard ones on request.
Connecting to the future
Solar energy is a clean alternative source of electricity. To make sure it is also a safe source, junction box and switch cabinet wiring has to be properly stripped, crimped and connected up. Using NWS wire stripping and crimping tools, electricians can handle wires and cables in line with all the applicable regulations and down to the millimetre. In this way, whether private houses, factory roofs or photovoltaic installations, they all become clean and safe players in the transition to renewable energy sources.